Dalmatic metro Dali plug-in one ten six module
The Dali plug-in module provides individual control of ten Dali luminaires and requires no addressing of the Dali ballasts on site The module provides powerful and flexible Dali control, total plug-in connectivity, distributed intelligence, and incorporates Lon technology for seamless interoperability with other Lon building services The module is equipped with ten individually addressed relays which save energy by switching off power to the ballasts at 0% output (avoiding wasteful standby power consumption) and also allow control of non-Dali light sources The metro one ten six enables single or two-fix installation. A robust frame, designed for screw or drop-rod mounting, accepts a clip-in module with ports for the plug-in connection of incoming mains, luminaire outputs, buswire & control devices. The module accepts the plug-in connection of multisensors, presence detectors and switches | |
o Metro Dali plug-in one then six Product ref: 201B1 |
Benefits of the Dali plug-in one ten six The Dali plug-in module offers a number of benefits: Reduces the time and cost of commissioning by using pre-addressed ports which avoid the need to address Dali ballasts on-site. | Enable ballast replacement without the need to assign an address so simplifying maintenance. | Saves energy by switching off power to ballasts at 0% output so avoiding standby power consumption. | Enables the connection & control of non-Dali sources including tungsten lamps, fan-coils etc. |
|
Mounting details The metro one ten is designed for single or two-fix installation. The unit comprises: · A robust frame fixed on drop rods or via screws · A snap-in module Mount the frame with the arrow pointing up | |
dimensions (mm) 345 w x 210 h x 55 d (excludes plugs) 100 mm depth including capsule & plugs construction flame-retardant low smoke moulded housing ambient temperature / relative humidity 0 to +SO'C I 20% to 90% non condensing | technical details supply 1 x 220-240V- 50/60Hz single phase 10A lighting circuit protected by 10A MCB (3 pin plug-in connector supplied) Dali outputs 10 Dali dimming outputs. Dali ballasts are auto-addressed and do not require on-site addressing Module provides lamp/ballast failure per Dali output. Dali emergency devices connect to the Dali bus from the luminaire port switched 230V outputs 10 individually switched outputs (1 DA resistive, 3A inductive) 1 emergency test output local switch inputs 1 plug-in port (three-pin - sw1) for connection of conventional monetary action switch. 328mm 4 plug-in ports (two-pin - i1-i4) for connection of smart / Dali presence detectors, multisensors and scene-set devices: plug-in terminal block accepts max 1 sq.mm cable. network Lon bus inputs 2 plug-in ports for twisted pair Lon network bus connection (max 1.5 sq.mm cable). diagnostic LEDs Neon - shows 240v present. Power LED • shows secondary power circuit operational. Alert LED . indicates short on the sensor bus or issue with Communication card. Wink LED - winks when instructed through software Service LED - indicates fault mode. buswire specification 330 V rms - twisted pair Belden 7701 NH unshielded 22 AWG stranded. 600 V rms - twisted pair Belcom 4001 P22S54LSZH unshielded 22 AWG solid. |
Lon specifications Echelon LonWorks FT 5000 Smart Transceiver FTX3 free topology communications transformer 64k EEPROM Conforms to LonMark 3.4 guidelines and profiles 4 switch objects #3200 4 light sensor objects #1010 4 occupancy sensor objects #1060 10 open loop actuator objects #0003 4 occupancy controller objects #3071 4 light controller objects #3050 |
| |
| |